PRODUCT OVERVIEW
The direct acting self operated pressure regulating valve is composed of valve body, valve seat, valve core components and other parts. It is an energy-saving product that automatically regulates the pressure only by relying on the pressure change of the regulated medium without external energy. It can be used as a pressure control device for non corrosive (maximum temperature 350 ℃) liquids, gases, steam and other media. It is widely used in petroleum, chemical industry, metallurgy, light industry and other industrial departments and urban heating and heating systems.
PRODUCT MODEL AND SPECIFICATION
Category |
Pressure control regulating valve |
Differential pressure rising valve open |
Rear pressure regulating valve |
Front pressure regulating valve |
Differential pressure rising valve open |
Differential pressure rising valve open |
Hard seal |
Soft seal |
Hard seal |
Soft seal |
Hard seal |
Soft seal |
Hard seal |
Soft seal |
Model |
V230 D01 |
V230D01 |
V230D02 |
V231D02 |
V230D03 |
V231D03 |
V230D04 |
V231D04 |
Specifications |
DN15-250 |
MAIN TECHNICAL PARAMETERS
Nominal diameter mm |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
Rated flow coefficientKvs |
3.2 |
5 |
8 |
12.5 |
20 |
32 |
50 |
80 |
125 |
160 |
320 |
450 |
630 |
Nominal pressureMPa |
1.6、 4.0 |
Z value |
0.6 |
0.6 |
0.6 |
0.55 |
0.55 |
0.5 |
0.5 |
0.45 |
0.4 |
0.35 |
0.3 |
0.2 |
0.2 |
Maximum operating temperature ℃ |
V230 V231 |
Liquid ≤ 140, gas ≤ 80 |
Hard seal V230 |
Equipped with isolation tank ≤ 200 |
Equipped with isolation tank and extension ≤ 300 |
Equipped with isolation tank and heat sink ≤ 200 |
Pressure balancing element |
corrugated pipe |
Rolling diaphragm |
Flange standard |
DIA (Flange standard can also be provided according to user requirements) |
Valve body material | PN16: cast iron (working temperature ≤ 200 ℃); PN4.0: cast steel, cast stainless steel (working temperature ≤ 350 ℃)
|
Valve core material |
stainless steel; The soft seal is stainless steel inlaid rubber ring |
Maximum working pressure Mpa |
Weigh the pressure (pay attention to △ Pmax and the relationship between working pressure and working temperature) |
Note:
1. When liquid > 140 ℃ and gas > 80 ℃, the valve shall be inverted;
2. Z value: noise measurement coefficient, which is used to measure the noise. See the selection guide of self operated regulating valve for specific calculation.
MAIN DIMENSIONS AND WEIGHT
Nominal diameter mm |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
L mm |
150 |
160 |
180 |
200 |
230 |
290 |
310 |
350 |
400 |
480 |
600 |
730 |
B mm |
212 |
238 |
238 |
240 |
240 |
275 |
275 |
380 |
380 |
295 |
325 |
372 |
Approximate weightkg |
6.7 |
9.7 |
13 |
14 |
17 |
29 |
33 |
60 |
70 |
80 |
140 |
220 |
ACTUATOR SIZE AND WEIGHT
Effective area cm 2 |
32 |
80 |
250 |
630 |
D (mm) |
172 |
172 |
263 |
380 |
H (mm) |
440 |
435 |
440 |
520 |
Approximate weightkg |
7.5 |
7.5 |
13 |
28 |
Note: the total height and weight of direct acting self operated valve is the sum of the height and weight of control valve and actuator.